GRD16 flying/stacking grid

LR16B 2x 15” line-array bass

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC154 NL4 cable, 15meter

(cross-over LR16B 80Hz - 160Hz)

LR16 2-way active 2x 8”+RBN601

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC158 NL8 cable, 15meter

LSC0068 NL8 cable, 60centimeter

(cross-over LR16 160Hz - 1.2kHz.)

BF362 2x 18” subwoofer

ALC6 2x 3kW controller-amp

DDP Digital Drive Processor

LSC154 NL4 cable, 15meter

cross-over BF362 30Hz - 80Hz
1x

2x

1x (2 channels, 4 ohms ea.)

1x

2x (or 1x, running on 2 ohms)

 

6x

2x (4 channels, 2.7 ohms ea.)

2x

2x

4x

 

2x

1x (2 channels, 4 ohms ea.)

1x

2x
     
   
GRD16 flying/stacking grid

LR16B 2x 15” line-array bass

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC154 NL4 cable, 15meter

(cross-over LR16B 40z - 160Hz)

LR16 2-way active 2x 8”+RBN601

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC158 NL8 cable, 15meter

LSC0068 NL8 cable, 60centimeter

(cross-over LR16 160Hz - 1.2kHz.)
1x

2x

1x (2 channels, 4 ohms ea.)

1x

2x (or 1x, running on 2 ohms)

 

6x

2x (4 channels, 2.7 ohms ea.)

2x

2x

4x

 
     
   
GRD16 flying/stacking grid

LR16 2-way active 2x 8”+RBN601

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC158 NL8 cable, 15meter

LSC0068 NL8 cable, 60centimeter

(cross-over LR16 75Hz - 1.2kHz.)

BF362 2x 18” subwoofer

ALC6 2x 3kW controller-amp

DDP Digital Drive Processor

LSC154 NL4 cable, 15meter

(cross-over BF362 30Hz - 75Hz)
1x

6x

2x (4 channels, 2.7 ohms ea.)

2x

2x

4x

 

2x

1x (2 channels, 4 ohms ea.)

1x

2x
     
   
GRD16 flying/stacking grid

LR16 2-way active 2x 8”+RBN601

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC158 NL8 cable, 15meter

LSC0068 NL8 cable, 60centimeter

(cross-over LR16 75Hz - 1.2kHz.)

LR16B 2x 15” line-array bass

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC154 NL4 cable, 15meter

(cross-over LR16B 40z - 75Hz)
1x

6x

2x (4 channels, 2.7 ohms ea.)

2x

2x

4x

 

2x

1x (2 channels, 4 ohms ea.)

1x

2x (or 1x, running on 2 ohms)
     
   
GRD16 flying/stacking grid

LR16 2-way active 2x 8”+RBN601

ALC4 2x 2kW controller-amp

DDP Digital Drive Processor

LSC158 NL8 cable, 15meter

LSC0068 NL8 cable, 60centimeter

(cross-over LR16 70Hz - 1.2kHz.)
1x

6x

2x (4 channels, 2.7 ohms ea.)

2x

2x

4x

     
   
 

 

   
also see

  » Technology  
  » LR7 system components  
  » LR14 system components  
  » LR14 system configurations  
  » LR16 system components  
  LR14 system configuration  

downloads

LR16 system configurations (pdf)